In this video
- Remove the black protective caps on the indoor unit before connecting the line set
- A hiss of gas when the caps come off is just the factory nitrogen charge, not refrigerant
- Line up the flare nut perfectly straight and hand-tighten first to avoid cross-threading
- After hand-tightening, use a wrench to add one quarter turn (about 45 degrees)
- Don't overtighten - the copper and brass flare fittings can be damaged if you go too far
Questions this video answers
Why is gas hissing out when I take the caps off my mini-split line set fittings?
That's normal. Mini-split indoor units are shipped with a small nitrogen charge that keeps moisture and dirt out of the lines during manufacturing and shipping. When you loosen the caps you'll hear it escaping, but it's just nitrogen, not refrigerant, so there's nothing to be alarmed about.
How tight should I make a mini-split flare nut connection?
Hand-tighten the flare nut as far as it will go, then use a wrench to add one more quarter turn, roughly 45 degrees. That's tight enough to seal the connection without overtightening and damaging the copper and brass fitting.
Do I need a torque wrench to connect a mini-split line set?
A torque wrench is fine to use, but it isn't required. In the video, hand-tightening followed by a quarter turn with two ordinary wrenches gets the job done.
What does it mean if the flare nut won't thread onto the indoor unit easily?
If it doesn't turn on smoothly by hand, it's likely cross-threaded. Stop immediately, back the nut off, realign it so it's perfectly straight with the male flare, and start again.
Can you overtighten a mini-split flare fitting?
Yes. The fittings are made of copper and brass, and cranking them down too hard can tear the metal and ruin the connection. Snug is the goal, not as-tight-as-possible.
What size line sets connect to a mini-split indoor unit?
This demonstration uses a common pairing of a 1/4 inch line and a 3/8 inch line, each connecting to its matching size flare fitting on the back of the indoor unit.
Transcript
Read the full transcript
So the next step in our progression here is to connect the line set — this is the one that's going to go through the wall — to the fittings that are already on the indoor unit. The first thing you need to do is take off these black caps.
When the indoor unit is shipped or manufactured, there's nitrogen put in there to pressurize it and keep moisture and dirt out. As you loosen these caps — and these have already been loosened a bit because we've been playing around with this one — you'll hear the nitrogen coming out. Don't be alarmed, that's not refrigerant, it's just an effect of the packing process. Let it all come out, no problem.
This is the quarter-inch line. It needs to connect to, obviously, the quarter-inch line set. This is the male flare, and the female part here needs to connect perfectly straight onto the male for this to work.
Then you're going to hand-tighten this flare nut on here, and it should thread on very easily. If it doesn't, that means it's cross-threaded — stop, back off, and start again, because it needs to be threaded straight for it to line up. So hand-tighten it as far as you possibly can.
Then you're going to need two wrenches — one of them can be a torque wrench. Todd, the guy who's filming right now, has done a lot of these, and he just uses two normal wrenches. His rule is that after hand-tightening, you wrench-tighten one quarter turn, so that's about 45 degrees. That feels pretty tight.
Then we do the other one the same way. Tighten it as far as you can by hand, making sure everything is perfectly perpendicular to each other so the threading is correct and not cross-threaded. After doing it by hand, I don't even think you could get a quarter turn in there, but it's feeling very tight.
Don't overtighten it, folks — that will destroy the fitting, because it's only copper and brass here, and it will tear it apart. Tighten it snugly, and then you're done.