Got a refrigerant leak, a bad component, or an old system you're scrapping? Airspool's Dave and Todd show how to turn a free junkyard window air conditioner into a working refrigerant recovery machine, plus how to convert an empty refrigerant tank into a reusable two-way tank.

Jump to transcript

In this video

  • Strip a scrap window AC down to its compressor, condenser coil, and filter dryer, then add a flare fitting, check valve, and on/off switch to build a basic recovery machine.
  • Keep the condenser coil in the circuit so hot refrigerant gas cools into liquid before it reaches the tank, which keeps pressure down and speeds up recovery.
  • Turn a disposable, one-way refrigerant tank into a reusable two-way tank by cutting the valve stem and drilling out the internal flapper valve.
  • Hook up a standard gauge set to pump refrigerant from a live system into the homemade recovery tank, watching the low-side gauge until it reads near zero.
  • Know the four situations that call for recovering refrigerant: a failed component, an unknown or overcharged amount, a leak, or decommissioning a unit.

Questions this video answers

Can I build my own refrigerant recovery machine out of an old window air conditioner?

Yes. Strip a window unit down to its compressor, condenser coil, and filter dryer, add a flare fitting and a check valve, and you have a working, if slow, recovery machine for pulling refrigerant out of a mini-split, car AC, or whole-house system.

Why do you need to keep the condenser coil on a homemade recovery machine?

The condenser coil cools the hot refrigerant gas before it reaches the tank, so it arrives as liquid instead of hot gas. That keeps tank pressure lower and lets a small compressor recover refrigerant faster and more safely.

Can I reuse an old refrigerant tank to store recovered refrigerant?

Only after modifying it. Disposable refrigerant tanks have a one-way flapper valve inside that blocks refrigerant from going back in. Cutting the top off the valve stem and drilling out that flapper turns it into a reusable, two-way tank.

Can I mix different refrigerants in the same recovery tank?

No. Different refrigerants use different compressor oils, and mixing them contaminates the charge. Use a dedicated tank filled with the same refrigerant type, such as R-410A, rather than trying to put refrigerant from the unit itself back into a mismatched tank.

When do I actually need to recover refrigerant from a mini-split or AC system?

Four common cases: replacing a failed component in the refrigerant circuit, correcting an unknown or overcharged refrigerant amount, fixing a leak, or decommissioning a unit so the refrigerant doesn't vent into the environment when it's scrapped.

Is it safe to use a homemade refrigerant recovery machine?

It can work in a pinch, but Dave and Todd are clear it's not a permanent professional tool. You need to fully understand what you're doing, make sure any tank is completely empty before modifying it, and it's not something to bring into a customer's home.

Why does a refrigerant recovery machine whistle so loudly while it's running?

The whistling is just the sound of refrigerant gas being pushed quickly through a small opening in the line. It's normal and means the machine is working, not a sign of a problem.

Transcript

Read the full transcript

Dave: All right, guys, here's how to make a junkyard refrigerant recovery machine, why you want one, and how it works. So Todd, take it away — what have you got here?

Todd: This is a window unit. It was given to me for free, and I just made a few modifications to it — took out the indoor coil, disconnected the discharge line from the coil, and disconnected the line going to the indoor coil. So you'll have basically two pipes to connect: one where refrigerant goes in, and one where it comes out. I leave the condenser coil on because it helps cool the refrigerant off, and it'll get into the tank quicker than without it. Otherwise it'd be a high-temperature gas going in that would expand real quickly, so cooling it off a little bit matters — you need the condenser coil, really, because without it there's going to be too much pressure in the tank.

Dave: Oh yeah, a lot?

Todd: Well, not too much pressure, but the little compressor is going to have a hard time pedaling that hill.

Dave: Right, okay. So far on this machine — you said there wasn't an on/off switch. That was one of the things that was bad on it?

Todd: That's right, so I built my own on/off switch. Then I took off the indoor unit's blower fan and the indoor coil, because all you need is the condenser side of this window unit. I put a flare nut on the discharge line coming out of the coil so it'll be liquid going into the tank. You don't have to use a set of gauges like this one — you could use regular gauges with hoses. I just did this because it was a leftover set I wasn't using anymore. You'll also need to add a fitting; I put a check valve on the suction side only, because we plan on using this a time or two in the future. It's a way to shut it off and not let air or moisture get in there.

Dave: What if the machine you want to get the refrigerant out of is R-410A, and your window unit is R-134A or something — can you use that, or no?

Todd: Well, you're not going to find a 134A window unit, but if you do come across an R-22 unit, the compressor in it uses different oil than a 410A system does, so you wouldn't have clean refrigerant that way — the oil would contaminate it. Having a fresh tank like this with just 410A in it, using the same oil, means you don't have to take the refrigerant out of your unit, put it in that tank, and then put it right back in.

Dave: So the machine is made now, but we need to make the tank, right?

Todd: Right. One more thing I want to point out — I left the filter dryer intact on the suction line going to the compressor. That helps keep contaminants from the unit and the hoses out of the system.

Dave: Okay, so what's the story with this tank?

Todd: These aren't like the old days, when you could reuse tanks — nowadays you can't. Let me take this off so you can see what I'm doing. These tanks are one-way; there's a flapper right at the top that closes if you try to push something back through it, so it won't let refrigerant back in. What we're going to do is cut the very top of the valve stem off, right here, which will let the valve unscrew and come completely out of the way. Then we'll take a drill bit, shove it down there, and drill out the flapper so it'll allow refrigerant to go back in.

Dave: All right, so that's like a check valve or something?

Todd: Yeah, like a check valve, exactly.

Dave: All right, so you're going to cut it — you've got your normal pipe cutter here.

Todd: Yeah, this is steel, so it's going to take a couple of rotations to cut through, but I have confidence you'll do it.

Dave: At what point are you cutting it — does it have to be right on the stem?

Todd: You can get as high as you can get it. There's just a little lip on the edge of the valve stem holding the valve in, so the higher, the better.

Dave: Okay, and I've got it all the way up against the valve — that's as high as I can get.

Todd: All right, that'll take a couple of minutes, so let's push pause. Then we'll remove this red piece here.

Dave: Yeah, we'll unscrew it, take it out of there, and then bring over a drill with a bit that'll drill out the flapper, and it'll be a two-way tank.

Todd: Okay, cool. So let's push pause for a moment.

Dave: All right, we're making some progress here. Todd, what have you done so far?

Todd: We successfully removed the valve out of the tank so we could get to the flapper — it's kind of hard to see, but if you look real closely, you can see it down in there. It almost looks like a toilet flapper.

Dave: Right, and if that doesn't come out, nothing will go back into the tank. But you said you could drill it out, or not?

Todd: Yeah, I'm going to try to pull it out with some needle-nose pliers first, but if I can't, we'll just drill it out. And make sure the tank is completely empty before you do any of this.

Dave: Right, important safety point. Obviously, if you have a full tank of R-410A, you don't want to lose that — you don't want to lose it for the money, you don't want to hurt the environment, and you don't want to hurt yourself. So make sure the tank is good and empty before trying any of this.

Todd: And this isn't really meant to be a permanent solution for a recovery tank — it's for when you're in a pinch. You've got to know what you're doing, otherwise you might hurt yourself. This isn't something you'd want to take into a customer's house.

Dave: All right, we've got our drill together — we're going to punch a hole through that flapper.

Todd: The important thing is to lay it on its side, at least, to keep shavings from dropping down into the tank. It's just plastic, so it drills a hole that quick, that easy — tap it out, and that's it. No more flapper. It actually came right out.

Dave: All right, now for the next stage — we've got to put the valve back in.

Todd: Same valve. The O-ring fits nice and snug; just make sure not to cross-thread it. There we go, should be very smooth. Yeah, it's going to be a little snug, but it was a little snug coming out too — just make sure you go in straight. You'll probably want to use a pair of pliers to run it in there if you're not as strong as me. There you go, and just make sure it goes down and shuts off. All right, that's it.

Dave: Now you're going to connect it. One more important thing to remember: now that the ring's been cut, that's what holds this valve in here, so if you have refrigerant in there under pressure and you unscrew this too far, it'll go off like a bottle rocket.

Todd: Right, don't unscrew it too far — just enough to let the gas through.

Dave: Okay, so how many revolutions?

Todd: You only really need about one and a half, and then you're open to the tank.

Dave: Okay, so next we're going to test it. All right, now you're going to use a normal gauge set, like you'd use on any other unit you're working on.

Todd: I just have this one set up a little differently, like I said, for display purposes. But just like you'd hook up onto your outdoor unit, you want to put this onto the suction side, like you're going to pump the unit down. We've got the hose hooked up to the unit on the service port — normally there'd be refrigerant lines connected to the unit, but this is just a practice unit, so your refrigerant lines would connect on the ends here. This valve you can go ahead and close — it doesn't need to be open.

Dave: Which valve remains open?

Todd: The bottom one you can close; the top one stays open. And then you hook your suction line up from the homemade recovery unit.

Dave: All right, so when would you actually need to do this?

Todd: Well, there are only a few reasons you'd ever have to pull all the refrigerant out. One, if you had a failed component in the refrigerant circuit in the outdoor unit that you need to replace, the refrigerant has to come out first. Two, if you put too much refrigerant in and you don't know how much is actually in there anymore, you're best off pulling it all out, weighing it, and then weighing the correct amount back in. Three, you've got a leak somewhere and you need to fix it, so you have to pull the refrigerant out to make the repair. Or four, if you're demoing a unit out and throwing it in the junkyard — you want to keep the refrigerant both because it's expensive and because it's extremely bad for the environment to let it vent out in a junkyard. So you save money and save the environment by pulling it out before you demo the unit.

Dave: All right, showtime.

Todd: Yeah, I hope it works.

Dave: Let's hope so.

Todd: It's not going to be super fast — most recovery machines, especially the smaller ones, take a while. You're just going to watch this gauge until it gets down close to zero.

Dave: So this compressor is smaller than your unit here, probably, right?

Todd: This is probably a 9,000 BTU unit, I think — yeah, something like that.

Dave: All right, so that's roughly half the size of that one, right?

Todd: But it'll still recover it — it'll just take a few more minutes, and it'll build up a lot of pressure to push the refrigerant into the tank, too.

Dave: Any other questions while we're waiting on this? Let's push pause. Is it moving at all yet, or no?

Todd: Oh yeah, it's moved a little bit.

Dave: Okay, let's push pause and we'll come back here in a moment.

Todd: All right, that was user error — this line wasn't connected. Now everything's getting sucked in, and it's working pretty well now that all the valves are open. So if you do add a check valve, make sure you open it when you turn the machine on.

Dave: Yes, so the moral of that story is: if you put a check valve on there, make sure you open it before you start all this. But this is doing a lot of whistling — why is that?

Todd: It's just pushing gas quickly through a small opening.

Dave: Right, pushing gas through a small opening is going to whistle, but it's working. All right, let's push pause for the next 20 seconds.

Dave: We're back. All right, take a look at this gauge — you'll see it's down by zero, which means we've successfully pulled all the refrigerant out of that unit and put it into the tank. Go ahead and shut the valve; you can see it's showing a negative now. Check these valves.

Dave: So you were saying this would be much higher if we didn't have the condenser here, right?

Todd: Right — it would be hot gas going into the tank, and it would build a lot more pressure, so it would take longer and run at a higher pressure without keeping the condenser on here. Right now, it's going in there in liquid form, so there it is. Close this valve — you'll have a little bit left over in the hoses that'll spill out, but you're talking a minuscule, de minimis amount.

Dave: All right, so in conclusion — if you're ever 250 miles from town and you have to recover some refrigerant out of your car, maybe…

Todd: Yeah, you could do it for a car unit too.

Dave: Now you know how to make a recovery machine out of an old window unit, and a recovery tank out of an old refrigerant tank. But other than that, don't try this at home — this is kind of evil-genius-type stuff here, right?

Todd: Yeah, we don't want anybody getting hurt.

Dave: All right, this is just one of our ideas. All right, thank you.

Written by Airspool Team

The crew that designs, tests, and ships every Airspool unit. We write the guides we wish we'd had when we started — plain-English, DIY-first, and honest about the tradeoffs.

Free download

What they're hoping you never read.

✓ It's yours.

Grab your copy right here, right now:

Download the guide (PDF) ▸

A copy is also on the way to your inbox.

Instant PDF download. Unsubscribe anytime.

The 7 Ugly Truths guide cover

Get the next guide in your inbox

Install tips, savings math, and straight answers. No spam, unsubscribe anytime.

A couple enjoying a cozy autumn living room with an Airspool unit.Crisp days.
Cozy homes.

A LITTLE SOMETHING FOR YOUR NEXT SEASON

Fall into savings.

$100 off

Make yourself comfortable. Join our email list and we’ll send your Fall discount code.

$100 off orders of $1,500 or more. Merchandise subtotal before tax and shipping. One use per customer. Cannot be combined with other discount codes.