In this video
- The EPA banned new production and importation of R410A equipment starting January 1, 2025, capping new refrigerants at a global warming potential (GWP) of 700
- R32 (GWP 675) and R454B (GWP 466) are the two leading R410A replacements, and both are mildly flammable A2L refrigerants
- R32 is unpatented, needs roughly 40% less refrigerant charge, and already dominates mini-split markets in Europe and Asia
- R454B is a blend of 69% R32 and R1234yf, chosen by manufacturers like Trane, Carrier, and York/Johnson Controls, while Lennox is opting for R32
- R410A isn't disappearing overnight — distributors have three years to sell existing inventory, so it should remain available well into the 2030s
- Airspool is developing its own R32-based solar mini split
Questions this video answers
Why is R410A refrigerant being banned?
The EPA is banning new production and importation of R410A equipment starting January 1, 2025, because R410A has a high global warming potential. The agency is capping newly manufactured refrigerants at a GWP of 700, and R410A is well above that limit.
What refrigerant will replace R410A in mini-splits?
Most manufacturers are switching to either R32 (GWP 675) or R454B (GWP 466), both of which meet the EPA's new GWP cap and run at a similar efficiency and pressure to R410A, which made it easier to adapt existing equipment designs.
Are R32 and R454B refrigerants flammable?
Yes, both are mildly flammable A2L refrigerants. R32 needs about a 14% concentration in air to ignite and R454B about 11%, but neither one ignites without an open flame present, and HVAC technicians will need new certification and training to work with them safely.
Can I still buy R410A equipment or refrigerant after 2025?
New production and importation of R410A stops on January 1, 2025, but distributors have three years to sell off existing inventory. That means R410A machines and refrigerant jugs will likely still be available well into the 2030s.
What's the difference between R32 and R454B?
R32 is a single, unpatented refrigerant that needs roughly 40% less charge and already dominates mini-split and VRF markets in Europe and Asia. R454B is a patented blend of 69% R32 and R1234yf, chosen by manufacturers like Trane, Carrier, and York/Johnson Controls, while Lennox is opting for R32.
Will Airspool mini-splits use R32?
Yes. Dave says Airspool has an R32 solar-powered mini split in development, following the broader industry shift toward R32 for smaller ductless systems.
What does GWP mean for refrigerants?
GWP stands for global warming potential, a measure of how much a refrigerant contributes to warming compared to CO2. The EPA is capping newly manufactured refrigerants at a GWP of 700, which is why higher-GWP options like R410A are being phased out in favor of R32 and R454B.
Is R32 still patented by Daikin?
No. Daikin held patents on how to manage R32 efficiently inside a sealed split system, but opened those patents for anyone to use. R32 itself has been unpatented since around 1980, so many manufacturers now use it, and it tends to be less expensive than the patented R454B blend.
Transcript
Read the full transcript
Hey guys, Dave with Airspool here, and the research has been conducted, strategies have been drafted, and decisions have been made in terms of which refrigerants will be replacing R410A. Likely it'll be one of the two shown here: R32 or R454B. We'll talk about why those two, when this is happening, and how or if it will be affecting you personally.
So refrigerants aren't real great for the environment. R12 and R22 especially were bad, and created a crisis back in the 80s and 90s. Actually, back in 1974, a couple of scientists found that a hole was forming over Antarctica because those refrigerants had chlorine in them that was attaching to the ozone molecules in the stratosphere and breaking them down. So UV radiation, UVB, didn't have anything to stop it. Luckily this was over Antarctica and not where more people live, because this amount of UVB radiation would likely give people skin cancer and cataracts, kill off plankton, and affect photosynthesis. In fact, the effect on the ecology in general could be worse than just having a little bit of a cataract and skin cancer problem. It took 22 years, but in 1996 R12 was banned for new manufacture and importing of new machines, and in 2010 the same happened with R22. R134a pretty much supplanted R12, and R410A took over for R22.
The problem with these two newer refrigerants is that they both had zero for ODP, ozone depleting potential, but a higher global warming potential, especially in the case of R410A. Whether you buy into it or not, the EPA does buy into it. They looked at the fact that from 1850, and for 880,000 years prior, the amount of CO2 in the atmosphere was around 250 parts per million. That started to jump up at the beginning of the Industrial Age, really ramped up after 1900, to the point where it's 423 parts per million now. The temperature has also been going up, in pretty much a perfect correlation to the amount of CO2 in the atmosphere. Temperatures are up about 1.5 degrees Celsius now over 1850, a little bit less than 3 degrees Fahrenheit. You may already be affected by global warming or climate change if you own or work at a ski resort, if you're a farmer, or if you happen to live in California, Texas, or Florida, where there have been more of these multi-billion dollar catastrophic events, which have been tripling your insurance.
So anyway, the EPA is a believer. They're capping the global warming potential of refrigerant at 700 starting January 1, 2025. Both R32 and R454B comply with this. R454B has an especially low GWP of only 466, versus 675 for R32. A lot of manufacturers are saying, hey, we don't want to keep screwing around every couple of years changing our refrigerant, let's commit to R454B now and we should be good until maybe the EPA lowers the max to 500 or whatever. That's part of the strategy. Also, R410A to R454B isn't exactly a drop-in swap, but it's a similar efficiency and similar pressure to running R410A machines, so it was less work to change the current machines to work with R454B.
Then there's a factor for both of these refrigerants that isn't a good one: both of them are A2L refrigerants. A3 is the most flammable, that'd be like propane. Other refrigerants we've had in the past are A1, not flammable at all. So the bad news is these new refrigerants are slightly flammable. R32 actually needs a 14% concentration in the air for it to ignite, R454B only needs 11%, but once R32 ignites it's more prone to propagating the flame. There's a guy who goes by Tom Cat on YouTube, see if you can find his video. It shows in a closed chamber testing propane, R454B, and R32, and you can see that if there's a spark, it doesn't do anything to any of them. If there's an open flame, they'll light as long as the open flame is there; take away the flame and they won't ignite. But you can imagine larger units, like the ones being used with R454B, if you had one of these units up on a rooftop and there's a lot of refrigerant coming out and there's a fire nearby, that could potentially be a real problem. It's something technicians who work with these refrigerants are going to have to get certified and learn how to handle. Line set connectivity and other things are going to change slightly too.
So I guess we're taking one for the team here for now. Maybe 10 years from now there'll be a refrigerant with no GWP, no ODP, and A1, non-flammable, but right now this is what we have, and this is what's going to help our grandkids have more stability in terms of global warming and climate change. We're taking one for the team for them at this point, I think.
Meanwhile, R32 is already very well established in Europe and Asia, with about 160 million machines already out there, and probably another 40 million machines a year once North America comes online. The rumor was that Daikin had patents on R32, but nobody has had patents on R32 itself since maybe 1960; it's been unpatented since around 1980. It was first developed back in the 1960s, and it's already in R410A, which is half R32, and in R454B, which is 69% R32. So it's already well known. The patents Daikin actually had covered how to manage R32 efficiently within a closed system, within one of these split or mini-split systems, how to maximize its efficiency. But they've opened up those patents and are allowing anyone to use them. Why? Because they manufacture both R32 units and the refrigerant itself, so it's probably good news for them the more people that are using R32. There are many other manufacturers of R32 too, though.
So R32 is probably going to be less expensive than R454B, because it isn't patented, whereas R454B is patented, and also you need less of it to run a machine. It takes a lot of re-engineering of these machines, but once that's done, they can run with potentially 40% less refrigerant, so they need a lot less energy. The manufacturers of R32 are claiming, hey, EPA, look at the fact that we don't need to use as much electricity, so we're not burning as much natural gas or coal to run these machines, since that's how electricity is still mostly made these days. They've probably got a lobbying effort in Washington saying keep us at our higher GWP number because we're actually lower when you look at the grand scheme of things, and R454B's backers are probably saying the exact opposite.
R32 also claims that, since it's a single refrigerant and not a mixture like R454B (which is R32 plus 31% R1234yf), there's an advantage. If there were a leak in an R454B machine and more R32 got out than R1234yf, then the temperature at which the refrigerant changes state could shift, which would mean more changes needed to the expansion valve and less predictable behavior. To avoid that, you'd have to suck out all the refrigerant and start fresh with new R454B, which could be expensive. But R454B's backers are claiming, no, in fact we're just like R410A, there's no glide issue. We'll have to see what happens here in the coming years, since it's still up in the air.
So, R454B has been found, or is going to be found, in bigger units from Trane, Carrier, and York, made by Johnson Controls, all of which I witnessed at the AHR show a couple weeks ago in Chicago, going with R454B. Some larger manufacturers, like Lennox, are opting for R32. I'm sure some smaller manufacturers are opting for R454B too, but in general these larger units, and Emerson, the maker of some of these larger unit compressors, are going with R454B. R32 is very dominant already in Europe and Asia in mini-splits and VRF, variable refrigerant flow, units. So on the larger side, you're probably going to see, or you are seeing, larger ductless VRF units with big 10-ton condensers and multiple indoor heads running R32.
So both of these refrigerants, you're going to see them both around, jury's still out on whether there'll be one clear winner, but probably both of them will stick around. R410A isn't going away right away, just the production, manufacturing, and importation after January 1, 2025. Distributors have three years to sell off their existing inventory of R410A jugs, so it'll probably be around well into the 2030s.
Here at Airspool, starting soon, we're going to have an R32 solar-powered mini split, so check out Airspool on our website and on our YouTube channel here, called Airspool. Thanks for your time.